Crouse-Hinds Crouse-Hinds Arktite® General Electric EBBRA604 TT60 3 Dust-Ignitionproof Grounding Style 2 Raintight Interlocked Receptacle With 60 A Circuit Breaker, 480 VAC, 250 VDC, 60 A, 3 Poles, 3 Wires, Natural

Selected IDW_IMAGE_71e52b1fa3ed9b525503cb4b6e7597d610b19e6349623be1753de2148a80b83e.jpg
IDW_IMAGE_71e52b1fa3ed9b525503cb4b6e7597d610b19e6349623be1753de2148a80b83e.jpg

Features

  • Rugged, corrosion-resistant, cast copper-free aluminum construction
  • Accepts compatible Arktite® plug of same rating and configuration
  • Mechanical interlock mechanism for dead front construction
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
  • A spring door receptacle, located at the bottom of the unit, is mechanically interlocked with the circuit breaker operating mechanism for safe and dependable operation
  • Plug and receptacle contacts cannot be made or broken under load
  • The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is de-energized
  • Operating handles can be padlocked in either on or off positions
  • Breakers are trip-free of the handles and will open under short circuit or overload even if the handle is locked in the on position
  • Component operating handles located through the right side wall of the body permits visual confirmation of correct component assembly and operation
  • Semi-clamshell enclosure design, with an external machined flat joint flame path between body and cover makes interior components easily accessible
  • Minimum enclosure to enclosure spacing with little interference between the opened cover and an adjacent enclosure
  • Copper-free aluminum hinges allow the cover to swing well out of the way
  • Stainless steel, quick release, captive, hex head cover bolts
  • Stainless steel springs provide clear indication cover bolts are fully retracted from body
  • Versatile, internal operating mechanisms allow for field adjustment to accommodate popular manufacturer's breakers
  • Simple, straightforward installation of breaker on pre-drilled mounting plate within enclosure
  • Neoprene cover gasket permanently attached to the cover seals out moisture
  • Tap-on mounting feet

Description

Crouse-Hinds Arktite® General Electric Interlocked Receptacle, Dust-Ignitionproof Grounding Style 2 Raintight, Series: EBBR, 480 VAC, 250 VDC, 60 A, 3 Pole, 3 Wires, NEMA 3/3R/12/7BCD/9FG NEMA Rating, Copper-Free Aluminum, Natural, 23.95 in L x 14.06 W x 10.25 in D Dimensions